Perfusion and Oxygenation Imager

#moorO2FLO

Simultaneous tissue perfusion and oxygenation imaging

  • We can't recommend Moor instruments highly enough. The technology is at the cutting edge and the support second to none.

    Paul Sumners, PhD
    London South Bank University

  • I expect to be using Moor Instrument’s technology for many years to come!

    Faisel Khan, PhD
    Ninewells Hospital & Medical School

  • We have found Moor equipment to be extremely dependable and innovative.

    Dean L. Kellogg, Jr., MD, Ph.D
    University of Texas Health Science Center

  • In a nutshell, moorFLPI-2 is the most user-friendly system for studying cerebral blood flow regulation in rodents.

    Chia-Yi (Alex) Kuan, MD, PhD
    Emory University School of Medicine

  • It goes without saying that the company's imaging technology itself is superb!

    Gourav Banerjee
    Leeds Beckett University

  • Laser Doppler Imager is a standard accurate method we now use in our cerebral blood flow and brain perfusion in our laboratory.

    Momoh A. Yakubu, PhD
    Texas Southern University

  • I cannot rate the company or the staff highly enough.

    Jim House, PhD
    University of Portsmouth

  • Moor Instruments have consistently provided excellent help and support for my research.

    Kim Gooding, PhD
    University of Exeter Medical School

The moorO2Flo perfusion and oxygenation imager is designed to simultaneously image tissue perfusion and relative tissue oxyhaemoglobin and deoxyhaemoglobin concentration change.

The moorO2Flo combines Moor Instruments’ existing laser speckle contrast technology for perfusion imaging (moorFLPI-2) with reflectance spectroscopy for oxygenation change imaging.

  • Non contact imaging techniques.
  • Blood flow and oxygen videos of any exposed tissue (skin or surgically exposed tissues).
  • Real-time video frame rates to capture dynamic changes in flow and oxygen – up to 20 frames per second, with each frame containing 1 x blood flow image, 1 x oxyHb image, 1 x deoxyHB image and 1 x colour photograph.
  • Best spatial resolution of 10 microns per pixel to reveal detailed morphology.
  • 10 x optical zoom to image areas from 15cm x 20cm to 5.6mm x 7.5mm with motorised zoom and autofocus.
  • Add multiple “regions of interest” to assess and quantify blood flow and oxygen changes in real time and post measurement. Area of ROIs calculated automatically.
  • Colour photo image matches blood flow and oxygen images precisely to aid identification of features.

The following products are AVAILABLE TO BUY ONLINE and work with the moorO2Flo


Moor Instruments are committed to product development. We reserve the right to change the specifications below without notice.

WARNING: The moorO2Flo emits flashing light which may potentially trigger seizures for people with photosensitive epilepsy. Do not use the moorO2Flo in the presence of individuals with photosensitive epilepsy.


Quality Control

The moorO2Flo is CE marked.

Measured Parameters

Tissue perfusion, in PU.
Relative oxygenated and deoxygenated haemoglobin concentration change, in AU.

Working Distance

100-380 mm (measured from front edge of enclosure).

Imaging Area

5.6mm x 7.5mm (maximum zoom, minimum distance).
150mm x 200mm (minimum zoom, maximum distance).

Image Resolution

116 x 150 pixels for perfusion and haemoglobin images (low resolution).
576 x 748 pixels for perfusion and haemoglobin images (high resolution).
580 x 752 pixels for colour photo/video images.

Combined Imaging Frame Rate

20 frames per second.
1 Frame consists of: 1x perfusion image, 1x oxyHb change image, 1x deoxyHb change image and 1x colour video image.

Operating Environment

Indoor laboratory use.
Temperature range: 15 – 30°C.
Atmospheric pressure: 86-106 kPa.
Humidity: 20-80%, non-condensing.
Maximum altitude: 2000 m.
Lighting conditions: Near-dark, controlled light environment or used inside a light proof enclosure.

Storage And Transportation Environment

Temperature range: 5 – 45°C.
Atmospheric pressure: 50-106 kPa.
Humidity: 20-80%, non-condensing.

Power Source

AC mains, 100-230 V, 50-60 Hz.

Dimensions

Scan head: 230x140x230 mm (WxHxD), 2.3 kg
PSU: 105x55x170 mm (WxHxD), 0.7 kg

Laser Classification

Class 1 (IEC 60825-1:2014).

Measurement Laser

Emission pattern: Diverging circular beam.
Wavelength: 785nm ± 10nm
Maximum power: 100mW, Accessible power below IEC. 60825-1:2014 Class 1 limits.

Aiming Lasers

Emission pattern: Collimated.
Wavelength: 650nm
Maximum power: 0.1mW per laser.

Intended Use

The moorO2Flo is intended for use in research and educational life science applications only. The moorO2Flo is not intended to be used for medical diagnostic or therapeutic purposes.