{"id":7974,"date":"2018-11-23T09:02:40","date_gmt":"2018-11-23T09:02:40","guid":{"rendered":"https:\/\/www.moor.co.uk\/applications\/flap-monitoring-post-op\/"},"modified":"2025-04-09T10:50:58","modified_gmt":"2025-04-09T10:50:58","slug":"flap-monitoring-post-op","status":"publish","type":"m_applications","link":"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/","title":{"rendered":"Flap Monitoring (Post-Op)"},"content":{"rendered":"<p>Tissue blood flow measurements of flaps and replanted tissues provided by laser Doppler could be used to provide an early indication of flap failure before clinical signs are apparent. Both surface and buried flaps can be monitored. The alarm level can be set manually and are set relative to baseline flow rather than for &#8216;normal&#8217; values because of natural spatial variations in flow. Signs of a healthy flap are a pulsatile LD blood flow waveform due to the cardiac cycle and a stable or steadily increasing trend. Fluctuations in LD blood flow are also good signs. These are due to vasomotion and physiological responses. Signs of a failing flap include lack of pulsatility, a falling trend and lack of fluctuations. Please note: these products are not for use as a diagnostic tool and should only be used in a research environment with appropriate local approvals.<\/p>\n","protected":false},"featured_media":0,"template":"","tags":[],"class_list":["post-7974","m_applications","type-m_applications","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Flap Monitoring (Post-Op) - Moor Instruments<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/\" \/>\n<meta property=\"og:locale\" content=\"zh_CN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Flap Monitoring (Post-Op) - Moor Instruments\" \/>\n<meta property=\"og:description\" content=\"Tissue blood flow measurements [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/\" \/>\n<meta property=\"og:site_name\" content=\"Moor Instruments\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/MoorInstruments\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-09T10:50:58+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:site\" content=\"@moor_hq\" \/>\n<meta name=\"twitter:label1\" content=\"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 \u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/\",\"url\":\"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/\",\"name\":\"Flap Monitoring (Post-Op) - Moor Instruments\",\"isPartOf\":{\"@id\":\"https:\/\/www.moor.co.uk\/#website\"},\"datePublished\":\"2018-11-23T09:02:40+00:00\",\"dateModified\":\"2025-04-09T10:50:58+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/#breadcrumb\"},\"inLanguage\":\"zh-Hans\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.moor.co.uk\/zh-cn\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Flap Monitoring (Post-Op)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.moor.co.uk\/#website\",\"url\":\"https:\/\/www.moor.co.uk\/\",\"name\":\"Moor Instruments\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.moor.co.uk\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.moor.co.uk\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"zh-Hans\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.moor.co.uk\/#organization\",\"name\":\"Moor Instruments\",\"url\":\"https:\/\/www.moor.co.uk\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"zh-Hans\",\"@id\":\"https:\/\/www.moor.co.uk\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.moorclinical.com\/wp-content\/uploads\/2018\/10\/logo-30.png\",\"contentUrl\":\"https:\/\/www.moorclinical.com\/wp-content\/uploads\/2018\/10\/logo-30.png\",\"width\":298,\"height\":49,\"caption\":\"Moor Instruments\"},\"image\":{\"@id\":\"https:\/\/www.moor.co.uk\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/MoorInstruments\",\"https:\/\/x.com\/moor_hq\",\"https:\/\/www.linkedin.com\/company\/2523249\",\"https:\/\/www.youtube.com\/user\/MoorInstruments\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Flap Monitoring (Post-Op) - Moor Instruments","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/","og_locale":"zh_CN","og_type":"article","og_title":"Flap Monitoring (Post-Op) - Moor Instruments","og_description":"Tissue blood flow measurements [&hellip;]","og_url":"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/","og_site_name":"Moor Instruments","article_publisher":"https:\/\/www.facebook.com\/MoorInstruments","article_modified_time":"2025-04-09T10:50:58+00:00","twitter_card":"summary_large_image","twitter_site":"@moor_hq","twitter_misc":{"\u9884\u8ba1\u9605\u8bfb\u65f6\u95f4":"1 \u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/","url":"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/","name":"Flap Monitoring (Post-Op) - Moor Instruments","isPartOf":{"@id":"https:\/\/www.moor.co.uk\/#website"},"datePublished":"2018-11-23T09:02:40+00:00","dateModified":"2025-04-09T10:50:58+00:00","breadcrumb":{"@id":"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/#breadcrumb"},"inLanguage":"zh-Hans","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.moor.co.uk\/zh-cn\/applications\/flap-monitoring-post-op\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.moor.co.uk\/zh-cn\/"},{"@type":"ListItem","position":2,"name":"Flap Monitoring (Post-Op)"}]},{"@type":"WebSite","@id":"https:\/\/www.moor.co.uk\/#website","url":"https:\/\/www.moor.co.uk\/","name":"Moor Instruments","description":"","publisher":{"@id":"https:\/\/www.moor.co.uk\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.moor.co.uk\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"zh-Hans"},{"@type":"Organization","@id":"https:\/\/www.moor.co.uk\/#organization","name":"Moor Instruments","url":"https:\/\/www.moor.co.uk\/","logo":{"@type":"ImageObject","inLanguage":"zh-Hans","@id":"https:\/\/www.moor.co.uk\/#\/schema\/logo\/image\/","url":"https:\/\/www.moorclinical.com\/wp-content\/uploads\/2018\/10\/logo-30.png","contentUrl":"https:\/\/www.moorclinical.com\/wp-content\/uploads\/2018\/10\/logo-30.png","width":298,"height":49,"caption":"Moor Instruments"},"image":{"@id":"https:\/\/www.moor.co.uk\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/MoorInstruments","https:\/\/x.com\/moor_hq","https:\/\/www.linkedin.com\/company\/2523249","https:\/\/www.youtube.com\/user\/MoorInstruments"]}]}},"_links":{"self":[{"href":"https:\/\/www.moor.co.uk\/zh-cn\/wp-json\/wp\/v2\/m_applications\/7974","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.moor.co.uk\/zh-cn\/wp-json\/wp\/v2\/m_applications"}],"about":[{"href":"https:\/\/www.moor.co.uk\/zh-cn\/wp-json\/wp\/v2\/types\/m_applications"}],"version-history":[{"count":4,"href":"https:\/\/www.moor.co.uk\/zh-cn\/wp-json\/wp\/v2\/m_applications\/7974\/revisions"}],"predecessor-version":[{"id":146628,"href":"https:\/\/www.moor.co.uk\/zh-cn\/wp-json\/wp\/v2\/m_applications\/7974\/revisions\/146628"}],"wp:attachment":[{"href":"https:\/\/www.moor.co.uk\/zh-cn\/wp-json\/wp\/v2\/media?parent=7974"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.moor.co.uk\/zh-cn\/wp-json\/wp\/v2\/tags?post=7974"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}