Лазерная допплеровская система мониторинга

#moorVMS-LDF

Усовершенствованный мониторинг кровотока с помощью лазерного допплера и мониторинг температуры

  • We can't recommend Moor instruments highly enough. The technology is at the cutting edge and the support second to none.

    Paul Sumners, PhD
    London South Bank University

  • Laser Doppler Imager is a standard accurate method we now use in our cerebral blood flow and brain perfusion in our laboratory.

    Momoh A. Yakubu, PhD
    Texas Southern University

  • In a nutshell, moorFLPI-2 is the most user-friendly system for studying cerebral blood flow regulation in rodents.

    Chia-Yi (Alex) Kuan, MD, PhD
    Emory University School of Medicine

  • It goes without saying that the company's imaging technology itself is superb!

    Gourav Banerjee
    Leeds Beckett University

  • Moor Instruments have consistently provided excellent help and support for my research.

    Kim Gooding, PhD
    University of Exeter Medical School

  • I cannot rate the company or the staff highly enough.

    Jim House, PhD
    University of Portsmouth

  • I expect to be using Moor Instrument’s technology for many years to come!

    Faisel Khan, PhD
    Ninewells Hospital & Medical School

  • We have found Moor equipment to be extremely dependable and innovative.

    Dean L. Kellogg, Jr., MD, Ph.D
    University of Texas Health Science Center

Прибор для лазерного допплеровского мониторинга кровотока и мониторинга температуры moorVMS-LDF является высокопроизводительным модульным прибором медицинского класса исполнения для использования в клинике и в лаборатории. Использование технологии цифровой обработки сигнала дает Вам портативный, легкий модуль с превосходными техническими характеристиками, качеством и надежностью по рекордно доступной цене.

Для сложных исследовательских приложений программное обеспечение прибора — moorVMS-PC – поддерживает одновременное управление модулями управления сдавливающей манжетой, ионофорезом и нагреванием кожи для воспроизводимых воздействий на кровоток, а также регистрацию данных с помощью нового 8-канального модуля регистрации данных moorVMS-DAQ.

Технические характеристики и особенности прибора moorVMS-LDF

  • Одно- и двухканальные модификации прибора
  • Многоканальность: Комбинируйте модули для многоканальной системы с поддержкой на уровне программного обеспечения для Вашей идеальной конфигурации. Конструкция корпуса, позволяющая размещать модули «стопкой» друг над другом обеспечивает при этом экономное расходование рабочего пространства.
  • Зонды с чипом памяти «Memory Chip Probe»: для широкого диапазона применений. Калибровочные константы сохраняются в самом зонде с функцией установленного по времени напоминания о повторной калибровке. Встроенное измерение температуры для накожных зондов.
  • Легко читаемые показания: высококонтрастный, белый ЖК-дисплей с подсветкой.
  • Продвинутое программное обеспечение для ПК, управляемого Windows: с широкими аналитическими возможностями и автоматическим генератором отчетов. Смотрите ссылку для более детальной информации по программному обеспечению (справа).
  • Легко подключаемый: аналоговая (0-5 В, миниатюрный байонетный соединитель) и цифровая (USB) передача данных в реальном времени включены в стандартную комплектацию для подключения к системам сбора данных.
  • Конструкция медицинской категории: предназначен как для клинического, так и для исследовательского применения.
  • Многоязыковой тренировочный DVD: для постоянной справочной информации.
  • Подтвержденная надежность: лучшая на рынке 5-летняя гарантия производителя.

The following products are AVAILABLE TO BUY ONLINE and work with the moorVMS-LDF


Этот раздел содержит наиболее частые вопросы, которые возникают у наших заказчиков касательно прибора moorVMS-LDF. Если у Вас есть вопросы, которых нет в приведенном ниже списке, пожалуйста, напишите нам по электронной почте. Мы будем рады помочь Вам и ответить на Ваши вопросы!


Q. Отличается ли качество измерений с помощью moorVMS-LDF от качества измерения с помощью других ваших моделей?
A. Все наши приборы разработаны и произведены для клинического/медицинского применения, включая и moorVMS-LDF. Мы не пожертвовали ни высоким качеством измерений, ни характеристиками прибора. Использование новейшей технологии обработки сигнала цифровым процессором позволяет нам предложить этот прибор по очень привлекательной цене.

Q. Как передаются данные с системы moorVMS-LDF?
A. В отличие от системы DRT4 (снята с производства), прибор moorVMS-LDF не имеет внутренней памяти для хранения данных, поэтому Вам будет нужно подключить систему к персональному компьютеру, записывающему устройству или системе регистрации данных для постоянной записи данных. Каждый прибор moorVMS-LDF будет подключаться к Вашему персональному компьютеру через порт USB. Вы можете подключить несколько приборов мониторинга moorVMS-LDF для создания Вашей многоканальной конфигурации. Также на задней панели прибора имеются разъемы BNC для подключения регистратора или системы сбора данных (напряжение 0 -5 В, полное масштабирование).

Q. В скольких точках одновременно я могу проводить измерения с помощью moorVMS-LDF?
A. Прибор moorVMS-LDF обеспечивает реальную гибкость для сознания многоканальных конфигураций. Приборы мониторинга могут быть подключены к любому порту USB на Вашем персональном компьютере, а если нужно подключить больше – используйте USB-разветвитель. Наше программное обеспечение для персонального компьютера будет поддерживать такие конфигурации.

Q. Как часто прибор должен калиброваться?
A. Некоторые наши пользователи проводят калибровку каждый день, другие – менее часто. Важным моментом является то, что температура помещения должна как можно менее варьироваться каждый раз, когда Вы проводите калибровку. Имеется риск «излишней калибровки» - избыточной калибровки в течение дня – которая может быть вредной, если имеются большие температурные колебания. Это может привести к изменениям в броуновском движении полистирольных микросфер. Мы рекомендуем при научных исследованиях проверять калибровку не реже раза в месяц. Калибровка также является хорошим индикатором состояния зонда. Поврежденный зонд не будет калиброваться!

Q. Как я могу использовать прибор moorVMS-LDF с другими «протокольными» модулями?
A. Прибор moorVMS-LDF в сочетании с программным обеспечением moorVMS-PC обеспечивает наиболее гибкое решение для интеграции с приборами мониторинга кровотока, модулем мониторинга тканевой оксигенации (moorVMS-OXY), ионофорезом (MIC2), нагревателем кожи (moorVMS-HEAT), контроллером сдавливающей манжеты (moorVMS-PRES), блоком сбора данных (moorVMS-DAQ), по Вашему выбору. Программное обеспечение выступает в роли «центра коммуникации» связывающего все модули вместе и обеспечивающего реализацию протоколов контроля и анализа в автоматическом режиме.

Q. Что такое зонды MemoryChip?
A. зонды MemoryChip сохраняют свою индивидуальную калибровочную информацию внутри своего собственного разъема. Когда Вы меняете зонды, или используете зонды на другом мониторе, всегда автоматически используются правильные данные по калибровке (соответствующие конкретному зонду).

Q. Нужно ли очищать кожу перед измерениями?
A. Да – мы рекомендуем использование спиртовых салфеток. Мертвая, отслаивающаяся кожа может быть удалена путем мягкого удаления с помощью клейкой ленты. Это нужно сделать не менее, чем за 20 минут до измерений, чтобы позволить пропасть эффектам стимуляции.

Имеется множество ссылок, где описывается использование прибора moorVMS-LDF. Приведенный ниже список является небольшой выборкой таких публикаций. Пожалуйста, свяжитесь с нами для получения списка ссылок по выбранной Вами теме.


Alawieh, A., Wang, W., Narang, A., and Tomlinson, S., 2016.
Thromboembolic Model of Cerebral Ischemia and Reperfusion in Mice.
Methods Mol Biol. 1462, pp357-72.
Weblink

Dang, J., Mitkari, B., Kipp, M., and Beyer, C., (2011).
Gonadal steroids prevent cell damage and stimulate behavioral recovery after transient middle cerebral artery occlusion in male and female rats.
Brain, behavior, and immunity, 25(4), pp.715–26.

Van Duijnhoven, N. T. L., Janssen, T. W. J., Green, D. J., Minson, C. T., Hopman, M. T. E., and Thijssen, D. H. J., (2009).
Effect of functional electrostimulation on impaired skin vasodilator responses to local heating in spinal cord injury.
Journal of applied physiology (Bethesda, Md. : 1985), 106(4), pp.1065–71.

Gardiner, H. M., Barlas, A., Matsui, H., Diemert, A., Taylor, M. J. O., Preece, J., Gordon, F., Greenwald, S. E., and Hecher, K., (2010).
Vascular programming in twins: the effects of chorionicity and fetal therapy for twin-to-twin transfusion syndrome.
Journal of Developmental Origins of Health and Disease 3(3) (2012) 182–189.

Heimhalt-El Hamriti, M., Schreiver, C., Noerenberg, A., Scheffler, J., Jacoby, U., Haffner, D., and Fischer, D.C., (2013).
Impaired skin microcirculation in paediatric patients with type 1 diabetes mellitus.
Cardiovascular diabetology, 12(1), p.115.

Herzog, R., Zendedel, A., Lammerding L., Beyer, C., and Slowik, A., (2016).
Impact of 17beta-estradiol and progesterone on inflammatory and apoptotic microRNA expression after ischemia in a rat model.
J Steroid Biochem Mol Biol., S0960-0760(16), pp30332-6.

Høyer, C., (2013).
Diagnostic accuracy of laser Doppler flowmetry versus strain gauge plethysmography for segmental pressure measurement.
JOURNAL OF VASCULAR SURGERY, pp.1563–1570.

Høyer, C., Sandermann, J., and Paludan, J., (2013).
Diagnostic accuracy of laser Doppler flowmetry versus strain gauge plethysmography for segmental pressure measurement.
Journal of vascular

Jin, K., Xie, L., Sun, F., Mao, X., and Greenberg, D., (2011).
Corpus Callosum and Experimental Stroke Studies in Callosotomized Rats and Acallosal Mice.
stroke, 42(9), pp.2584–2588.

Klonizakis, M., Alkhatib, A., Middleton, G., and Smith, M., (2013).
Mediterranean diet-and exercise-induced improvement in age-dependent vascular activity.
Clinical Science, pp.579–587.

Liu, H., Kohl-Bareis, M., and Huang, X.,(2011).
Design of a tissue oxygenation monitor and verification on human skin
N. Ramanujam & J. Popp, eds. , 8087(0), p.80871Y–80871Y–10.

Liu, L., Cui, J., Song, C .J., Bian, J.S., Sparatore, A., Soldato, P . Del, Wang, X.Y., and Yan , C. D., (2012).
H(2)S-releasing aspirin protects against aspirin-induced gastric injury via reducing oxidative stress.
PloS one, 7(9), p.e46301.

Petersen, L. J., Zacho, H. D., Lyngholm, A. M , and Arendt-Nielsen, L., (2010).
Tissue viability imaging for assessment of pharmacologically induced vasodilation and vasoconstriction in human skin.
Microvascular research, 80(3), pp.499–504.

Petrofsky, J., Alshammari, F., Khowailed, I. A., Rodrigues, S., Potnis, P., Akerkar, S., Shah, J., Chung, G., and Save, R., (2013).
The effect of acute administration of vitamin D on micro vascular endothelial function in Caucasians and South Asian Indians.
Medical science monitor : international medical journal of experimental and clinical research, 19, pp.641–7.

Phillips, J. P., Cibert-Goton, V., Langford, R. M., and Shortland, P. J., (2013).
Perfusion assessment in rat spinal cord tissue using photoplethysmography and laser Doppler flux measurements.
Journal of biomedical optics, 18(3), p.037005.

Ogawa, Y., Kamijo. Y., Ikegawa, S., Masuki, S., and Nose, H., (2016).
Effects of postural change from supine to head-up tilt on the skin sympathetic nerve activity component synchronised with the cardiac cycle in warmed men.
J Physiol., Nov 8. [Epub ahead of print]

Roehl, A. B., Zoremba, N., Kipp, M., Schiefer, J., Goetzenich, A., Bleilevens, C., Kuehn-Velten, N., Tolba, R., Rossaint, R., and Hein, M., (2012).
The effects of levosimendan on brain metabolism during initial recovery from global transient ischaemia/hypoxia.
BMC neurology, 12, p.81.

Sönmez, T. T., Al-Sawaf, O., Brandacher, G., Kanzler, I., Tuchscheerer, N., Tohidnezhad, M., Kanatas, A., Knobe, M., Fragoulis, A., Tolba, R., Mitchell, D., Pufe, T., Wruck, C . J., Hölzle, F., and Liehn, E. A., (2013).
A novel laser-Doppler flowmetry assisted murine model of acute hindlimb ischemia-reperfusion for free flap research.
PloS one, 8(6), p.e66498.

Sørensen, H., Rasmussen, P., Siebenmann, C., Zaar, M., Hvidtfeldt, M., Ogoh, S., Sato, Kohei, Kohl-Bareis, M., Secher, N.H., Lundby, C., (2015).
Extra-cerebral oxygenation influence on near-infrared-spectroscopy-determined frontal lobe oxygenation in healthy volunteers: a comparison between INVOS-4100 and NIRO-200NX.
Clinical physiology and functional imaging, 35(3), pp177-184.

Sørensen, H., Rasmussen, P., Sato, K., Persson, S., Olesen, N.D., Nielsen, H.B., Olsen, N.V., Ogoh, S., Secher, Niels H., (2014).
External carotid artery flow maintains near infrared spectroscopy-determined frontal lobe oxygenation during ephedrine administration.
British journal of anaesthesia, 113, pp452-8.

Sørensen, H., Sc, M., Secher, N. H., Sc, D. M , Siebenmann, C., Rasmussen, P., and Ph, D., (2012).
Cutaneous Vasoconstriction Affects Near-infrared Spectroscopy Determined Cerebral Oxygen Saturation during Administration of Norepinephrine.
American Society of Anesthesiologists., 117(2), pp.263 – 270.

Yagi, S., Doorschodt, B. M., Afify, M., Klinge, U., Kobayashi, E., Uemoto, S., and Tolba, R. H., (2011).
Improved preservation and microcirculation with POLYSOL after partial liver transplantation in rats.
The Journal of surgical research, 167(2), pp.e375–83.

Компания Moor Instruments всегда продолжает совершенствовать свою продукцию. Мы сохраняем за собой право изменять параметры приведенной ниже спецификации без предупреждения.


ОПТИКА

Классификация лазеров по безопасности
Класс 1 согласно IEC 60825-1:2007
Класс 1 согласно 21 CFR 1040.10 and 1040.11
Максимальная выходная мощность 2,5 милливатт.
Длина волны лазера 785 нм ± 10 нм.
Угловое рассеяние лазерного света от конца зонда – 26 градусов.
Все спецификации включают кумулятивные неопределенности измерений и ожидаемые увеличения значений после производства.

ИЗМЕРЕНИЯ ПЕРФУЗИИ

ПОТОК
Точность: ± 10% относительно стандартного moorVMS-LDF Moor Instruments.
Точность: ± 3% измеряемой величины
Диапазон: 0-1000 перфузионных единиц

КОНЦЕНТРАЦИЯ

Точность: ± 10%
Прецизионность: ± 5% измеряемой величины
Диапазон: 0-1000 AU

ИНТЕНСИВНОСТЬ РАССЕЯНОГО СВЕТА
Точность: ± 10%
Прецизионность: ± 3%
Диапазон: 0-1000 AU

ТЕМПЕРАТУРНЫЕ ИЗМЕРЕНИЯ

Диапазон: 5-50 градусов Цельсия
Разрешение: 0.1°C, точность ± 0.3°C

ОБРАБОТКА СИГНАЛА

Ширина полосы пропускания: высокое пропускание – 20 Гц
Низкое пропускание – 3 килогерц*, 15 килогерц, 22 килогерц*
Выходная константа времени: 0,1 с, 0,5 с, 3,0 с и без фильтрации
Автоматический контроль уровня усиления и обнуления

*Функции, доступные только при использовании программного обеспечения для компьютера

ВЫХОДЫ ИНТЕРФЕЙСА

Цифровой ЖК-дисплей
Максимальная частота обновления данных – 40 Гц
0-1000 единиц перфузии
Интерфейс USB для подключения к персональному компьютеру
По 2 аналоговых выхода на канал, миниатюрные байонетные разъемы 0 – 5 Вольт.

ФУНКЦИИ ВСТРОЕННОГО ПРОГРАММНОГО ОБЕСПЕЧЕНИЯ

Флеш-память программируемая с персонального компьютера
Настройка шкалы выхода
Выбор ширины полосы пропускания

ОБЩИЕ ХАРАКТЕРИСТИКИ

Универсальный переключаемый источник питания, рассчитанный на напряжение 100-230 В, при потреблении 30 ВА, 50 – 60 Гц
Размеры ШхВхГ мм
moorVMS-LDF1 235 x 60 x 200
moorVMS-LDF2 235 x 80 x 200
Вес, кг
moorVMS-LDF1 1.4
moorVMS-LDF2 1.5
Режим работы: постоянный.

УСЛОВИЯ ХРАНЕНИЯ И ТРАНСПОРТИРОВКИ

Температура 0-45 градусов Цельсия
Влажность 0-80%
Атмосферное давление — 500-1060 миллибар (0,5 – 1,06 атмосферы)
Тип защиты от поражения электрическим током – Класс 1
Степень защиты от поражения электрическим током – Тип BF
Степень защиты от попадания жидкостей – IPX0 (не защищен)
Степень защиты против легковоспламеняющихся анестетиков – оборудование не предназначено для использования в присутствии смесей горючих анестетиков с воздухом или с закисью азота.

Компания Moor Instruments производит широкий диапазон зондов, предназначенных для того, чтобы помочь Вам получить доступ к кровотоку в практически любой ткани. Мы рады дать Вам рекомендации по применению наших зондов для Ваших конкретных приложений, и мы также надеемся, что следующие общие замечания будут полезны для Вас.


Накожные зонды имеются в двух основных конфигурациях оптических волокон: двух-волоконные или много-волоконные. Много-волоконные конструкции обычно имеют кольцо из восьми или менее «собирающих» волокон вокруг центрального «доставляющего» волокна. Это обеспечивает усредненный сигнал для большей области ткани, чем могло бы быть обеспечено обычной двух-волоконной схемой.

Накожные зонды обычно фиксируются на коже с помощью держателя зонда и двухстороннего клейкого диска, хотя они могут использоваться и в других приложениях (например, измерения на кости, на внутренних органах) и с другим оборудованием (например, для ионофореза). Пожалуйста, обратитесь к каталогу «Аксессуары и ионофорез». Пользователи moorVMS-LDF могут выбрать комбинированные зонды для лазерных допплеровских и температурных измерений.

Стандартная длина кабеля для всех зондов – 2 метра. По запросу могут быть поставлены зонды с большей длинной кабеля (код PXL). Весь диапазон держателей зондов для этих (и других) зондов описан на странице аксессуаров.

Зонды-иглы являются одними из наиболее универсальных зондов. Они могут использоваться для измерений на поверхности, вводиться в ткани или использоваться для измерений на отдельных сосудах. Компактная конструкция также оказывается полезной при измерениях в тканях с ограниченной доступностью, например, для зубов, конъюнктивы, и там, где требуются микроманипуляции.

Зонды могут фиксироваться по отношению к ткани с помощью обычного лабораторного штатива-манипулятора путем зажимания черной ацетатной «ножки».

Более глубокие измерения возможны с помощью помещения конца зонда в объем ткани (для этого лучше подходят более тонкие иглы — VP4 и VP4s). Наиболее тонкие иглы могут быть вставлены в некоторые ткани непосредственно, с помощью мягкого давления. Для больших игл может быть необходимо сначала проколоть ткань с помощью иглы для подкожных инъекций.

Использование специфических держателей зондов может еще больше расширить спектр применения зондов-игл. «Влажные» липкие наклейки для удерживания зондов могут быть использованы для того, чтобы «приклеивать» зонды к влажным поверхностям/слизистым оболочкам. Зубная мастика может быть использована для создания индивидуальных держателей проб для измерений на зубах. Загнутые зонды-иглы могут быть использованы для доступа к задней части зубов.

Хотя лазерные допплеровские измерения обычно не рекомендуются для оценки потока в единичном сосуде, имеются приложения, где эта технологи используется для оценки изменений кровотока в малых индивидуальных сосудах. Компания Moor производит широкую линейку держателей зондов, чтобы осуществлять такие измерения.

Эндоскопические зонды позволяют проводить внутренне исследование кровотока в тканях кишечника, бронхов, уретры и т.п. Имеется широкий диапазон диаметров зондов, чтобы соответствовать биопсийным каналам большинства эндоскопов. Все эти зонды выполнены из гибкой, но прочной нейлоновой трубки.

Зонды с наименьшим диаметром, хотя они требуют в целом более деликатного обращения, могут быть использованы с назогастральными трубками: наконечник назогастральной трубки удаляется, чтобы позволить рабочему концу зонда «выглядывать» для осуществления измерений.

Стандартная длина для всех эндоскопических зондов – 3 метра. Могут быть поставлены зонды большей длины (максимально до 4 метров), которые, в частности, могут быть полезны при работе с крупными животными (например, лошадьми).

Низкопрофильная конструкция используется либо там, где затруднен доступ (например, слизистая рта) или для уменьшения приложения давления, если зонд должен быть прикрыт повязкой. Имеются различные варианты, включая зонд с титановым диском и практически плоский силиконовый зонд.

Система VP10M100ST & VP10M200ST типа управляющий/одноволоконный зонд. Управляющие зонды имеют двухволоконную конструкцию и обеспечивают связь между прибором мониторинга и одноволоконным зондом.

Эта система обеспечивает ряд преимуществ по сравнению с обычными конструкциями зондов. В число полезных качеств входит:

1. Зонды малого диаметра (вплоть до 250 микрон) для измерений с минимальной инвазивностью.

2. Широкий выбор одноволоконных зондов для различных измерений. Вы можете всего лишь присоединить новый зонд для смены между измерениями тканях в мускулов, мозга, желудка и т.д. Данная система представляет собой экономичное решение, если Вы собираетесь проводить измерения в нескольких местах, при этом имея ограниченное число каналов для ЛДФ.

3. Одноволоконные зонды поставляются с повторно используемыми разъемами (код заказа PCN). Зонды могут легко стерилизоваться для повторного использования или использоваться как одноразовые (смотрите P10d, P10k,P10s-TCG). Компания Moor Instruments может также поставлять для Вас материалы для создания Вами собственных одноволоконных зондов.

4. При долговременных повторяющихся измерениях Управляющий зонд может отсоединяться, чтобы оставить одноволоконный зонд на месте между периодами измерения.