Laser-Doppler-Linienscanner

#moorLDLS2

Schnelle Laser-Doppler-Blutflussbildgebung

  • It goes without saying that the company's imaging technology itself is superb!

    Gourav Banerjee
    Leeds Beckett University

  • Moor Instruments have consistently provided excellent help and support for my research.

    Kim Gooding, PhD
    University of Exeter Medical School

  • I cannot rate the company or the staff highly enough.

    Jim House, PhD
    University of Portsmouth

  • I expect to be using Moor Instrument’s technology for many years to come!

    Faisel Khan, PhD
    Ninewells Hospital & Medical School

  • In a nutshell, moorFLPI-2 is the most user-friendly system for studying cerebral blood flow regulation in rodents.

    Chia-Yi (Alex) Kuan, MD, PhD
    Emory University School of Medicine

  • We have found Moor equipment to be extremely dependable and innovative.

    Dean L. Kellogg, Jr., MD, Ph.D
    University of Texas Health Science Center

  • Laser Doppler Imager is a standard accurate method we now use in our cerebral blood flow and brain perfusion in our laboratory.

    Momoh A. Yakubu, PhD
    Texas Southern University

  • We can't recommend Moor instruments highly enough. The technology is at the cutting edge and the support second to none.

    Paul Sumners, PhD
    London South Bank University

Das moorLDLS2 Linien – Scanner – System ermöglicht die Erfassung von Laser – Doppler – Bildern des Blutflusses der Mikrozirkulation mit einer Scanzeit von minimal 4 Sekunden. Das System basiert auf einem linienförmigen Laser und einem Vielkanaldetektor für die Laser – Doppler – Signale, die an 64 Messpunkte gleichzeitig erfassen werden. Die Eindringtiefe des Linienlasers ist vergleichbar mit der des moorLDI2 – Systems mit dem Vorteil einer deutlich schnelleren Bilderfassung.

Durch diese schnelle Bildaufnahme ist das System für Anwendungen geeignet, bei denen dynamische Änderungen zu schnell für eine konventionelle Laser – Doppler – Bildgebung erfolgen oder in denen die klinischen Bedingungen ein Herabsetzen der Scanzeit erfordern. Darüber hinaus ist bei einer hohen Zahl von Messungen die Zeit – bzw. Kostenersparnis erheblich.

Neben unserer Erfahrung in Anwendungen in der Klinik und in der Forschung bieten wir unseren Kunden auch eine breite Palette an Zubehör an.

Wie bei allen unseren Produkten ist die Qualität und Zuverlässigkeit hoch und daher gewähren wir eine zwei-jährige Garantie.

Das folgende Zubehör für den moorLDLS2 können Sie ONLINE KAUFEN


This section lists the more common questions our customers have with regards to the moorLDLS2. If you have a question you would like answered that does not appear below then please email us. We are happy to help!


Q. What is the penetration depth of moorLDLS2?
A. The penetration will depend to some extent on the optical properties of the tissue sampled. The measurement depth is equivalent to conventional single beam imagers so will include components from the superficial, nutritive layers as well as some influence from deeper and larger vessels.

Q. What is the largest area you can image with moorLDLS2?
A. The image area is dependent on the scan area selected as well as the distance from the scan head to the tissue. This allows the study of areas up to 20cm x 15cm.

Q. How often should the moorLDLS2 be calibrated?
A. The moorLDLS2 is factory calibrated. A user calibration kit is provided to enable checking of calibration and recalibration if necessary. It is good practice to check this routinely throughout an extended research period.

Q. How can I assess dynamic responses with moorLDLS2?
A. The moorLDLS2 is used in the same way as a conventional laser Doppler imager - changes from a baseline are commonly assessed. Measurement modes include single image (to assess variations within the same image), repeat image (to assess changes over extended periods) and continuous 64 channel single point assessments.

There are numerous references where our laser Doppler imagers are cited. The list below is a small selection. Please contact us for reference lists on your chosen subject.


Mistrík E, Dusilová Sulková S, Bláha V, Kalousová M, Knízek J, Moucka P, Herout V, Kadlec M, Stilec R, Sobotka L.
Plasma albumin levels correlate with decreased microcirculation and the development of skin defects in hemodialyzed patients.
Nutrition. 2010 Sep;26(9):880-5.

Murray AK, Moore TL, Manning JB, Taylor C, Griffiths CE, Herrick AL.
Noninvasive imaging techniques in the assessment of scleroderma spectrum disorders.
Arthritis Rheum. 2009 Aug 15;61(8):1103-11

Bal SM, Caussin J, Pavel S, Bouwstra JA.
In vivo assessment of safety of microneedle arrays in human skin.
Eur J Pharm Sci. 2008 Oct 2;35(3):193-202.

Bei Moor Instruments steht die Produktentwicklung an erster Stelle. Deshalb behalten wir uns das Recht vor, die unten angeführten Spezifikationen ohne Ankündigung zu ändern.


Messprinzip

Laser-Doppler-Linienscanner (Schnelle Scantechnik).

Laserschutzklasse

Klasse 3R. Schutzbrille im Lieferumfang.

Kalibrierung

Fabrikseitig kalibriert durch temperaturkontrollierten Motilitätsstandard. Einfache Kalibrierung durch den Benutzer durch die mitgelieferte Software und ein Kalibrierungskit.

Anzahl der Messkanäle

64 – d.h. 64 Pixel werden simultan gemessen.

Höchste Bildauflösung

256 x 64 Pixel.

Typische Scandauer

64 x 64 Pixel – 4 Sekunden.

Maximal gescannte Fläche

20 cm x 15 cm – Scandauer 13 Sekunden bei maximaler Auflösung.

Betriebsmodi

Einzelpunkt (1 bis 64 Kanäle), Einzelbild, Wiederholte Einzelbilder, Linienmessung.

Software

Basierend auf der Moor Instruments moorLDI-Software- über 15 Jahre nach Kundenwünschen verbessert.

Befestigungsmöglichkeiten

Tischhalterung oder klinischer Rollwagen mit Isolationstransformator.

PC-Anschlüsse

1 x USB und1 x Firewire (IEEE1394) Anschluss. Passend für Laptop / Desktop oder Panel-PC (keine spezielle Karten nötig).

Gewährleistung

2 Jahre, Teile & Arbeitslohn, erweiterte Serviceverträge erhältlich.

Gewicht/ Abmessungen

Scankopf (ca.) 19 cm x 30 cm x 18 (max) cm, Scankopf 3,2kg.